Despite progress in the scale-up of early infant diagnosis (EID) programs in the last decade, in 2018 only 51% of HIV-exposed infants received a diagnostic nucleic-acid test within the recommended two months of birth. Point-of-care (POC) testing has been shown to dramatically increase rates of early diagnosis and initiation of ART for HIV-positive infants. As national programs in sub-Saharan Africa incorporate POC EID technologies, it is critical to document the impact of POC EID within routine public sector programs and understand implications for national scale-up.
A 6-month pre-/post-evaluation comparing conventional laboratory (pre) to POC (post) EID testing using either Cepheid GeneXpert or Abbott mPima devices was conducted in 36 facilities across three countries, Cameroon, Ethiopia and Zimbabwe, between 2018-2019. On-site trainings for POC devices were held for facility and laboratory staff prior to implementation. Data were retrospectively extracted from routine records at health facilities for all infants (aged 0-2 years) tested. The primary outcome was the proportion of infants tested in which the infant’s caregiver received the test results within 28 days of sample collection (WHO recommendation, 2010). ART initiation within 28 days of sample collection was also analyzed for HIV-positive infants.
Before POC introduction, 2465 EID tests were conducted, of which 123 (5.0%) were HIV-positive. After POC implementation, 4288 tests were conducted, 189 (4.4%) of which were HIV-positive. POC EID resulted in faster turnaround times [median of 0 days (POC) vs. 40 days (conventional)] and POC EID results were more than four times as likely to be received by a caregiver within 28 days of sample collection (19.5% for conventional vs. 86.1% for POC; RR: 4.67; 95% CI: 1.51-7.83). The proportion of caregivers receiving results within 28 days of POC sample collection varied from 76.0% in Cameroon to 96.2% in Ethiopia (Table 1). Infants tested on POC had a much greater probabilty of initiating ART within 28 days (9.8% for conventional vs. 67.2% for POC; RR: 6.72; 95% CI 2.13-11.32).
POC EID significantly improved rates of test result returned to caregiver and ART initiation within routine care at public health facilities. However, in some settings gaps remained in timely results return and treatment initiation. To maximize the impact of faster testing through POC, programs must focus on ensuring test results are used and follow-on care is provided.