Abstract Body

Assays that measure the size of the latent reservoir with high sensitivity, precision and throughput are needed for clinical studies directed toward eradication. Droplet digital PCR (ddPCR) provides an efficient, standard-independent method to measure HIV DNA, but distinguishing between integrated and unintegrated molecular forms remains a challenge. Previous attempts to remove contaminating episomal and linear unintegrated DNA have been limited by low sensitivity or assay throughput. We sought to develop an assay specific for integrated HIV DNA by initial isolation of high-molecular weight DNA via automated pulse-field gel electrophoresis (PFGE) with the BluePippin system followed by ddPCR.

8E5 cells were grown in culture, while CD4 cells were enriched from PBMCs and infected with NL43 HIV for 7 days. DNA was extracted by Qiagen QIAamp DNA Blood Mini Kit. 8E5 DNA was loaded at 1000ng or 100ng while CD4 DNA was loaded at 500ng or 50ng per well into Pippin Gel 0.75% DF Cassettes, and separated using a PFGE protocol. After collection, DNA samples were assayed by ddPCR to measure HIV 2-LTR junction, HIV gag, and cellular RPP30. Recovery efficiencies were calculated by assuming that measured copy numbers were Poisson-distributed.

Preliminary PFGE protocols resulted in poor recovery of high molecular weight DNA (3-10%). Further optimization, including a custom high-pass PFGE protocol greatly improved recovery of high molecular weight DNA; 29-38% for 8E5 DNA, and 24-61% for CD4 DNA. Efficient recovery of high molecular weight DNA increased with the amount of loaded DNA. Contaminating episomal 2-LTR HIV DNA in infected CD4s was reduced by 98% for 500ng DNA (CI: 97-99%) and 97% for 50ng DNA (CI: 93-100%) as measured by ddPCR. In 8E5, which lack low molecular weight HIV DNA, HIV gag and RPP30 were recovered with similar efficiency. The coefficient of variation of the normalized HIV gag copy number per cell for the combined PFGE-ddPCR protocol was 14%.

Automated PFGE to remove episomal and linear species of HIV DNA permits the recovery of chromosomal HIV DNA with high purity and efficient recovery. This technology provides a sensitive and precise approach to the measurement of integrated HIV DNA with sufficient throughput for translational research studies.