Abstract Body

Background: Self HIV testing would contribute measurably to public health by helping more infected individuals become aware of their HIV status and therefore reducing HIV transmission. In 2012, the FDA approved the OraQuick In-Home test with oral (saliva) swab. INSTI HIV1/HIV2R, a finger-stick whole blood test, used for years by healthcare professionals, more sensitive, provides a test result in 5 minutes and could be an alternative. Little is known about the feasibility of self-testing with finger-stick whole blood tests. Methodology: We conducted a prospective monocentric study (September 2013). Eligibility requirements included: > 18, HIV positive patient without mental or physical handicap. After agreement, patients performed self testing with INSTI HIV1/HIV2R with a detailed notice. The test was considered as correct if patient performed all steps alone with a correct interpretation of the results. Results: Forty patients (mean age = 45.8, sex ratio M/F = 3.4) were included with primary education (13), secondary education (14), tertiary education (13). Viral load was < 1,6 log for 25 patients (62.5%). Five (12.5%) patients did not able to complete all steps of the test. Of the remaining 35 HIV positive patients, 25 had a positive test result (sensitivity=71.4%), 1 negative (patient with undetectable viral load), 2 invalid, 7 non-reactive. Mean time to perform testing was 6 minutes 40 s (min = 3 min 20s, max = 13 min 30s): mean time for blood collection = 3 min 50 s and for mixing and reading = 3 min 20 s. The test was correctly performed by 19 patients (47,5%). Main reasons for failure were lack of blood (11), wrong lancet utilization (4), and in the mixing of the samples (3). Factors associated with success were: age (40.4 vs 50.8, p=0.02) and tertiary education (53% vs 14%, p = 0.01). The pain was low for 21 (52.5%) patients and 19 (47.5%) patients declared no pain. The notice was considered as adapted for 27 patients and relatively adapted for 13. Performing the test was considered very easy for 22 patients and quiet easy for 18. Thirty four (85%) patients would recommend this test to a friend. Because of low rate of feasibility, the study was stopped. Conclusions: Feasibility of self testing with INSTI VIH1/VIH2R appears to be low in our study. The main reason for failure was blood collection. However a finger-stick whole blood test does not appear to be a barrier to self testing. An improvement in the technique of whole blood collection should be made.