In resource-limited settings, smear microscopy for tuberculosis (TB) diagnosis lacks sensitivity especially in HIV co-infection, resulting in undiagnosed TB and high mortality. Various molecular tests have been developed to improve TB diagnosis. The loop-mediated isothermal amplification assay (TB-LAMP test) can be staged with minimal infrastructure and is rapid, low cost and detection is with the naked eye. We assessed feasibility and accuracy of Eiken TB-LAMP test in the diagnosis of TB in a high prevalence TB/HIV rural setting in Uganda.
From October 2013-February 2014, TB-LAMP was carried out on sputum specimens from presumptive TB adults at a district hospital and two low-level health centers in Kiboga district where smear microscopy is the available routine diagnostic option and power cutoffs are frequent. TB LAMP was performed by a technician who had no prior experience in the technology, after a week of training; a simple room without bio-safety cabinet was used. MTB sputum cultures were used as reference standard.
Of the 233 presumptive TB (126 at hospital; 107 at low-level health centers); 113 (48.5%) were HIV-infected; 55% male; median age 40(IQR 30-53). Compared to MTB culture, overall sensitivity and specificity of TB-LAMP were 55.4% (95 CI 44.1-66.3) and 98.0% (95 CI 94.3-99.6) respectively. In hospital setting, TB LAMP sensitivity and specificity were 62.2% (95 CI 44.8-77.5) and 97.8% (95 CI 92.1-99.7) respectively, while in low-level health centers, sensitivity and specificity were 50% (95 CI 34.9-65.1) and 98.4% (95 CI 91.2-100) respectively. Among HIV-infected participants, TB LAMP overall sensitivity and specificity were 52.3% (95 CI 36.7-67.5%) and 97.1% (95 CI 89.9-99.6) respectively compared to MTB culture. Similar accuracy indices among HIV-infected individuals were observed on stratification by setting. A summary of TB LAMP accuracy indices stratified by setting, determined using various reference standards are shown in the uploaded table.
In this high HIV prevalence rural setting, TB LAMP performs better than conventional smear microscopy in the diagnosis of MTB in both hospital and low-level health facilities, as well as among HIV-infected individuals. TB LAMP can easily be performed following a short training period and in the absence of sophisticated infrastructure and expertise. We recommend use of TB-LAMP test in the diagnosis of TB in rural resource-limited settings including low-level health facilities.