Abstract Body

Long-acting (LA) antiretroviral interventions hold promise to revolutionise HIV therapy and prevention and mitigate key concerns regarding adherence to oral medications. The current study investigated a biodegradable subcutaneous implant derived from a polymer formed entirely from an emtricitabine (FTC) prodrug (POP implant).

For in vitro studies, POP implants were incubated in 1 mL of phosphate buffered saline containing human liver microsomes at 37 °C/ 125 rpm for 72 hours. Every 24 hours, 500 µL samples were taken and replaced with 500 µL of fresh buffer to maintain sink conditions. For in vivo evaluations, two POP implants (2mm x 15mm each) were inserted subcutaneously into the scapular region of male Wistar rats under anaesthetic with 3% isoflurane. Plasma samples were obtained 1-6 hours and 1-31 days post implantation. FTC concentrations were quantified using a validated LC-MS/MS assay.

Eleven candidates were screened in vitro and three were selected for animal studies with in vitro release rates of 145, 59 and 7 µg/day for POP1, POP2 and POP3, respectively. In vitro release rate was determined from the linear phase of the profile. The plasma pharmacokinetics of the three implants are shown in Figure 1, with a Cmax of 5581, 2306 and 1847 ng/mL, AUC0-tlast of 14,614, 4644, and 4616 ng.days/mL and Cmin of 10, 27 and 32 ng/mL for POP1, POP2 and POP3, respectively. Plasma concentration profiles following implantation could be empirically described by a 2-compartment model with first order input, reflecting the drug release and flip-flop kinetics rather than the intrinsic pharmacokinetic disposition of FTC seen previously for intravenous administration. Apparent clearance was 0.7, 1.6 and 2.0 L/h/kg with final phase half-life of 6.6, 17.3, and 14.6 days for POP1, POP2 and POP3 respectively. In vitro-in vivo correlation for AUC0-tlast and Cmax revealed R2 values of 0.87 and 0.93, and an inverse correlation with Cmin (R2 = 0.98), demonstrating the relationship between in vitro release and in vivo exposure.

These data support LA drug delivery from a biodegradable polymer implant manufactured exclusively from an FTC prodrug for over 31-days. The relevance of human target exposures in rat studies are unclear, but concentrations remained above the reported FTC EC90 for 14, 10 and 7 days for POP1, POP2 and POP3, respectively. Ongoing studies seek to optimise exposures that can be achieved for FTC and POP implants manufactured from other antiretroviral drugs.