Background
The HIV reservoir is the major barrier to a cure. Although most proviruses are defective, intact genomes can reactivate after treatment interruption and drive viral rebound. Distinguishing intact from defective proviruses is therefore critical for cure research but remains challenging. Q4ddPCR is a 4-target droplet digital PCR assay (env, Ψ, gag, pol) for HIV reservoir quantification that classifies proviruses through a standardized reporting framework. Benchmarking against 3,650 near-full-length proviral sequences demonstrated high specificity. Q4ddPCR reveals steeper longitudinal reservoir declines compared with IPDA, reduces misclassification of defective proviruses and is robust to sequence variation. Here, we evaluated its performance for total HIV DNA quantification and its predictive value for inducibility, measured by quantitative viral outgrowth assay (QVOA).
Methods
Samples from 28 people with HIV (PWH) on suppressive ART (median duration 21 years, range 13-36) were assayed by Q4ddPCR and 5’LTR-ddPCR for total HIV DNA quantification. In 16 participants, QVOA was performed and p24 ELISA results were compared with intact proviral frequencies measured by Q4ddPCR and IPDA.
Results
Total HIV DNA measured by Q4ddPCR and 5’LTR-ddPCR were highly correlated and concordant (r = 0.87, p < 0.0001, rhoc = 0.84). Compared with IPDA, Q4ddPCR yielded lower intact frequencies, consistent with improved specificity. Reservoir sizes estimated by Q4ddPCR and IPDA were median 59-fold and 115-fold higher, respectively, than those measured by QVOA. Following the Q4ddPCR decision tree framework, intact frequencies correlated with QVOA (r = 0.64, p = 0.01), whereas IPDA showed no significant correlation (r = 0.24, p = 0.39, Fig. 1). Higher-order Q4ddPCR readouts such as 4-target or env-Ψ-pol showed the strongest correlations with QVOA. Importantly, the predictive value for inducibility was determined by the specific target combination rather than the number of amplified targets alone.
Conclusions
Q4ddPCR enables scalable and specific quantification of total HIV DNA and intact proviruses, making it well suited for clinical trials. Through a standardized decision-tree framework that emphasizes specificity, Q4ddPCR shows stronger alignment with inducibility than IPDA, supporting its use as a surrogate for functional reservoir measurements.
Table or Figure