Abstract Body

Background:

Real-time-reverse-transcription-Polymerase-Chain-Reaction (RT-PCR) is the gold-standard diagnostic test to confirm SARS-CoV-2 infection however RT-PCR is expensive requiring specialist laboratories. Alternatively, optimised nucleic-acid-tests such as SARS-CoV-2-reverse-transcriptase-Loop-mediated-isothermal-AMPlification (SARS-LAMP) could minimise costs and enable testing in settings without specialist laboratories. We evaluated the diagnostic test accuracy (DTA)-(sensitivity detecting cycle-threshold (CT) values <30; specificity >95%), acceptability and user-friendliness of SARS-LAMP test.

Methods:

Following optimisation of SARS-LAMP, a DTA study was conducted at Queen-Elizabeth-Central-Hospital (QECH) COVID-19 testing centre in Southern Malawi between September 2021-January 2022. Nasopharyngeal swabs were collected and tested for SARS-COV-2 by laboratory technicians using SARS-LAMP at Kamuzu-University-of-Health-Sciences (KUHes) laboratory. The reference standard test was defined as RT-PCR or rapid-antigen-testing (RAT) for SARS-CoV2 performed using any commercial platform at QECH. We calculated sensitivity and specificity of SARS-LAMP compared to existing commercial tests. SARS-LAMP’s user-friendliness by laboratory technicians (n=4) and acceptability by suspected cases of COVID-19 and contacts (n=68) were assessed using semi-structured interviews. Likert scales were analysed using summation analysis. Major themes and subthemes were identified.

Results:

105 retrospective nasopharyngeal swabs samples were analysed during optimisation and SARS-LAMP had sensitivity-73.7%(95% CI:65.3%-89.2%); specificity-100%(95% CI:100.0%-100.0%). The prospective DTA study recruited 450 participants using convenience sampling. Median age-37 years (IQR:28-57 years); 248/450(55%)-male, 61/450(13.6%)-contacts, 259/450(58%)-vaccinated. 233/450 (52%) had comorbidities, 192/450 (43%) were SARS-COV-2 positive, 5/192(3%) were admitted to ICU, 2 deaths occurred. 87/192(45.3%) had RT-PCR (CT<30); SARS-LAMP detected 64/87(73.6%):sensitivity-73.6%(95% CI:63.0.%-82.4%); specificity-100% 95% CI:98.6%-100.0%). 67/192(34.9%) were RAT positive; SARS-LAMP detected 37/67(55.2%) :sensitivity-55.2% (95% CI:42.6%-67.4%); specificity-100% (95% CI:98.6%-100.0%). SARS-LAMP was 67/68(98%) acceptable to cases and contacts of COVID-19; 4/4(100%) user-friendly to laboratory technicians.

Conclusions:

SARS-LAMP’s sensitivity was comparable to previous studies. It was acceptable patients and user-friendly to laboratory technicians.