Abstract Body

Multipurpose prevention technologies (MPTs) are of interest to prevent unintended pregnancy and HIV. Uniquely designed, geometrically complex 3D printed intravaginal rings (IVRs) are an attractive delivery platform that can provide controlled drug release and tunable product user characteristics. We evaluated drug release, elimination, and safety of an MPT IVR in sheep and an Islatravir (EFdA)-eluting, HIV PrEP IVR in NHP.

IVRs were manufactured using Continuous Liquid Interface Production (CLIP™) 3D printing and EFdA, ethinyl estradiol (EE), and etonogestrel (ENG) were formulated individually or in combination. MPT IVRs (4.03-6.48 mg/kg EFdA, 0.05-0.07 mg/kg EE and 0.2-0.3 mg/kg ENG) were administered to 4 female sheep; and EFdA, EE and ENG were quantified in plasma and vaginal tissues and fluids over 14 days of insertion then 7 days after removal. Safety was assessed by colposcopy, optical coherence tomography, and vaginal biopsy. EFdA IVRs (4.6-10.3 mg/kg EFdA) were administered to 3 female NHP; and EFdA was quantified in plasma and vaginal tissues and fluids and EFdA triphosphate (tp) in PBMCs over 28 days of insertion then 3 days after removal. IVR safety was assessed ex vivo by a vaginal microbiome (VMB) system and in the vaginal epithelial cell (VEC) culture system.

Plasma EFdA concentrations of 1-10 ng/mL were maintained over 14 days in sheep and 28 days in NHP. EFdAtp was quantifiable in all 3 NHP over the observation window with all 3 NHP exhibiting EFdAtp concentrations above the therapeutic target for humans (50 fmol/10^6 cells). EFdA concentrations in vaginal tissues were 10-10^3 ng/g in sheep and 10^3-10^5 ng/g in NHP. In sheep, plasma EE (0.01-0.05 ng/mL) and ENG (0.3-0.9 ng/mL) were maintained over 14 days. Vaginal fluid concentrations of EE (1-10 ng/mL) and ENG (10-100 ng/mL) were comparable to NuvaRing® concentrations in sheep. MPT IVRs were well tolerated in sheep and did not induce mucosal disruption or epithelial thinning. These IVRs were also well tolerated in NHP and had no significant impact on cell health in VEC cultures and transplanted VMB. Sheep VMB were also unaffected.

We report the first 3D printed EFdA/EE/ENG MPT IVR and demonstrated sustained drug release over >150 days in vitro, 14 days in sheep, and 28 days in NHP. IVRs were well tolerated in vivo (sheep and macaque) and ex vivo (VMB and VEC). Next studies include improved IVR design with modeling, to optimize API dose and release rates for best PK and efficacy outcomes.