Ascertaining HIV status at time of death can be useful for identifying missed opportunities to diagnose and treat HIV infection. Routinely testing HIV status among deaths, though not commonly practiced, may complement vital statistics in Kenya, where cause-specific attribution to death is often not documented. Currently available and validated rapid test kits (RTKs) in Kenya require a blood sample, which is hard to draw from cadavers. To avoid logistical difficulties of blood-based HIV testing, a minimally invasive assay using oral fluid such as OraQuick®, may be an alternative. OraQuick® has previously been used in Kenya for HIV self-testing, showing a higher specificity than sensitivity. We verified the feasibility and diagnostic accuracy of OraQuick® for HIV screening among cadavers.
Trained morticians collected pre- and post-embalming oral fluids from 132 cadavers >18 months old at Jaramogi Oginga Odinga Teaching and Referral Hospital (JOOTRH) mortuary in Kisumu, Kenya. These were tested for HIV using OraQuick®. Test results from OraQuick® were compared with those obtained using national RTK algorithm on matched pre-embalming whole blood specimens as a gold standard (Determine® HIV and First Response® HIV 1-2-O). We calculated positive predictive value (PPV), negative predictive value (NPV), false detection rate (FDR), false omission rate (FOR), sensitivity and specificity of OraQuick® compared to the gold standard.
OraQuick had a sensitivity of 92.6%, (95% CI: 75.7 – 99.1) on pre and post-embalmed samples when compared to the gold standard. The specificity was 97.1% (95% CI: 91.9 – 99.4) and 95.2%, (95% CI: 89.2 – 98.4) pre and post-embalming respectively (Table1). The pre-embalming PPV of OraQuick® was 89.3% (95% CI: 71.8 – 97.7) and 83.3%, 95% (95% CI: 65.3 – 94.4) post-embalming. FDR was lower on pre-embalming compared to post embalming at 10.7% (95% CI 2.3 – 28.2) and 16.7%, (95% CI: 5.6 – 34.7) respectively. Only 2/27 (7%) were false negative. FOR pre-embalming (1.92%) and post-embalming (1.96%) were similar.
OraQuick® was found to more specific than sensitive on oral specimens from cadavers. Similar performance has been reported among living subjects. It is a convenient less invasive screening test for surveillance of HIV among cadavers within a mortuary setting.