We evaluated the pharmacokinetics of tenofovir alafenamide (TAF), an antiretroviral prodrug with high potency and potential for HIV Pre-exposure prophylaxis (PrEP), released from polycaprolactone (PCL) implants at the midway point of a 3-month study in rabbits.
PCL tubes (40 mm x 2.5 mm x 70 µm wall thickness) were fabricated by extrusion and loaded with a slurry of TAF and Castor Oil (2:1 ratio by mass). Devices were sterilized by gamma-irradiation post-fabrication. Ten female New Zealand white rabbits were surgically implanted with active (TAF; n=6) or placebo devices (n=4). Blood samples were taken 6 h post-surgery on day 0 and on days 1, 4, 7 and weekly thereafter, for TAF and tenofovir (TFV) drug quantification (lower limits of quantification: TAF, 0.03 ng/mL; TFV, 0.31 ng/mL). Peripheral blood mononuclear cells (PBMCs) were isolated from blood samples collected on days 7 and weekly thereafter, for TFV-diphosphate (TFV-DP) determination (as fmol/10[sup]6[/sup] cells). At day 49, some devices were recovered for residual drug analysis. Similar TAF devices were concurrently evaluated in-vitro in PBS at 37°C. In-vitro sampling occurred every other day and TAF release was measured by UV spectrophotometer.
TAF release in-vitro from the active devices followed a zero-order release kinetics (1.1±0.02 mg/d) during study period. Similarly, plasma concentrations indicated the implanted devices maintained a low systemic exposure of TAF with a median concentration of 0.4±0.1 ng/mL. Low systemic exposure to TFV was also demonstrated attaining a median concentration of 9.4±2.6 ng/mL. PBMC loading with TFV-DP was noted at the first sampling time point and was maintained throughout the study period at a median level of 1825±820 fmol/106 cells (or 9125 nM) (Figure 1). Residual drug analysis of the retrieved devices approximated the in-vivo release rate of TAF to be 1.1±0.01 mg/d. Of note, some animals exhibited cutaneous responses (i.e., encapsulation and swelling) to the active devices.
The sustained plasma TAF concentrations and the in-vivo release rate of the active implants correlated well with the in-vitro TAF release from similar devices. TAF implants maintained sustained PBMC TFV-DP concentrations for the duration of the 49d mid-point evaluation well above that predicted for HIV PrEP in humans. Taken together, these data indicate this TAF device is suitable for continued development as a long-acting subcutaneous implant for HIV PrEP.