Abstract Body

Measuring integrated HIV DNA (provirus) in PBMC is important in characterizing the circulating HIV reservoir. However, these measures can be confounded by the presence of non-integrated linear and circular forms of HIV DNA. The Alu-Gag assay combined with an efficiency assumption is the current standard assay to measure integrated HIV DNA. Droplet digital PCR (ddPCR) provides an efficient, standard-independent method to measure HIV DNA, but unable to distinguish between integrated and unintegrated molecular forms. Previously, utilizing pulse-field gel electrophoresis (PFGE) we have shown a 98% clearance of circular forms of HIV DNA. Here, we applied PFGE to purify high-molecular weight DNA from linear and circular HIV DNA forms, and then assayed for integrated HIV DNA by ddPCR. In a blinded fashion, results of proviral levels were compared between Alu-Gag and PFGE+ddPCR assays.

DNA was extracted from PBMC collected from 10 ART-suppressed persons. First, using between 2-63µg of extracted DNA, samples were quantified by a standard Alu-Gag assay. Second, 1µg of DNA was used to measure HIV 2-LTR, HIV Gag, and RPP30 without any prior separation by ddPCR. Third, 5µg of DNA from each sample was loaded per well of BluePippin Gel 0.75% DF Cassettes and separated using a PFGE 15kb High-Pass protocol, and levels of HIV 2-LTR, HIV Gag, and RPP30 were then measured by ddPCR.

Before PFGE separation, ddPCR detected episomal HIV 2-LTR in 6 samples and HIV Gag in all 10 samples. After processing with PFGE, HIV 2-LTR was undetectable while HIV Gag was still detected in all 10 samples. Cellular DNA recovery after PFGE, as measured by RPP30, varied between 9-42% with an average of 21% across all samples. Levels of integrated HIV DNA measured by Alu-Gag and PFGE proviral assays after unblinding were highly correlated (R=0.7051; p =0.023; Spearman’s Rank-Order Correlation).

The PFGE+ddPCR Integrated HIV DNA assay removed episomal and linear species of HIV DNA to enable detection of provirus efficiently with as little as 5 μg (<500,000 cells) from HIV-infected persons receiving suppressive ART. These results were comparable to the standard Alu-Gag proviral assay, but the PFGE+ddPCR assay required fewer cells and was less technically difficult. Thus, the proposed PFGE+ddPCR assay provides a sensitive and precise approach to the measurement of integrated HIV DNA with sufficient throughput for translational research cure studies measuring the circulating HIV reservoir.