HPTN 071 (PopART) is a community-randomized HIV prevention trial in Zambia and South Africa (SA) that includes a cohort of >30,000 adults. Initial HIV testing is performed in-country using a 4th generation test (Abbott ARCHITECT HIV Ag/Ab Combo Test, one run per sample); special procedures for sample and data management are used in-country to optimize data quality. HIV status is confirmed in the United States (US). We evaluated performance of the Abbott test as an HIV screening test.
Samples that were initially reactive with the Abbott test (Abbott POS) were tested in the US with a second 4th generation test (BioRad Combo); 10% of samples that were initially non-reactive with the Abbott test (Abbott NEG) were retested in the US using the Abbott test. Samples with discordant results (in-country and US results did not agree) were tested with the BioRad Multispot test, the BioRad Geenius test, and an HIV RNA test (cutoff of 40 or 400 copies/mL).
10,390 samples were tested in the US (5,563 from Zambia, 4,827 from SA; 7,695 Abbott POS; 2,695 Abbott NEG). 56 samples had discordant results. For the Abbott POS samples: 52/7,695 (0.62%) were non-reactive with the BioRad Combo test (25 from Zambia, 27 from SA). Further testing revealed that 4 were HIV-positive (the original Abbott test result was correct), 48 were HIV-negative (the original Abbott test results were false positive results; 1 case involved a sample mixup). For the Abbott NEG samples: 4/2,695 (0.15%) were reactive when retested with the same assay. One had a signal/cutoff (S/C) ratio of 1.25 and was non-reactive on a second repeat test. The other two had S/C ratios of 4.77 and 10.38; both were reactive with the BioRad Combo test, but had undetectable HIV RNA and non-reactive Multispot and Geenius tests. All 4 were classified as HIV-negative. Overall, 48/7,695 Abbott POS samples had an initial false positive test result and 0/2,695 Abbott NEG samples had a false negative result (sensitivity=100%; specificity=98.3%).
The Abbott Combo test performed well when screening for HIV infection in a large, population-level survey in Africa. Special data and sample management procedures likely contributed to the high quality of initial HIV screening test results in this study. Quality assurance testing was helpful for confirming HIV infection status, especially for those with an initially reactive Abbott Combo test result.