Abstract Body

Background: Accurate rapid diagnostic test (RDT) results are critical to HIV testing, care and prevention services. However, suboptimal storage at ambient temperatures above manufacturer-recommendation is common in sub-Saharan Africa. Re-reading of used test kits can provide valuable programmatic quality-assurance, and “late” reading is also commonly reported following HIV self-testing. We evaluated the effects of prolonged exposure to high temperatures on both initial accuracy, and reproducibility of late reads.

Methods: A cross-sectional diagnostic evaluation in Blantyre, Malawi. Consenting participants attending HIV testing services had parallel testing with 3 RDTs (OraQuick (oral), Determine 1/2™, Alere, Waltham, USA and Uni-Gold™ Recombigen® HIV, Trinity Biotech, Bray, Ireland): a) preincubated for 28 days at 37 s‹C as intact packages and b) the same 3 RDTs stored under optimal conditions (6 tests in total). All 6 kits were read by the study nurse at the recommended time, and then again by a laboratory technician on the same day and monthly for 12 months (although with reference to previous results). Optimally stored Uni-Gold/Determine/SD Bioline were used for the gold standard.

Results: Of 378 participants, 198 (53.4%) were male with median age 31 years (IQR 25-40). Compared to gold standard, sensitivity for normal and high temperature OraQuick, Determine and Uni-Gold are shown in the table below. All but 6 participants had concordant results from each of the 6 kits, with no discernable effect on accuracy from preincubation. One participant was positive on both OraQuick (optimal) and Determine (optimal), but negative on the other RDTs, and was classified as HIV-negative. A further 5 participants had false-negative results on one or more RDTs. Notably, 108 (28.6%) reported being on antiretroviral treatment (ART). Over 12 months of re-reading used OraQuick kits; 1 (0.3%) in both optimal-stored and high temperature groups changed from negative to positive (different clients). In both cases participants were known to be on ART.

Conclusions: This study showed that rapid diagnostic HIV test kits stored at prolonged high temperature did not appreciably affect diagnostic performance. Repeated reading of OraQuick kits up to 12 months after testing appears to be highly reproducible, although not recommended by the manufacturer. Clients seeking retesting while on ART maybe an increasing common cause of inaccuracy in HTC clinics.

viewer?TAG_ACTION=SECURE_FILE_DOWNLOAD&V