Background: HIV RNA viral load (VL) testing for patients on antiretroviral therapy (ART) has increasingly been recognized as a key component of patient monitoring, even in low-resource settings. However, due to financial and technical constraints, the routine implementation of virologic testing remains rare in most sub-Saharan Africa health facilities. Dried blood spots (DBS) have emerged as a potential low-cost substitute for standard plasma assays; however, their performance in large-scale field conditions has not sufficiently been assessed. In a prospective study in Uganda, we evaluate the ability of a novel whole blood finger-prick DBS assay to detect plasma viral load measures exceeding 1000 and 5000 copies/mL.
Methods: Samples were collected from over 3000 ART patients at nine hospitals and six health centers. 150-250 consecutive adult patients who presented for care and had been on treatment for a minimum of six months were recruited into the study at each facility. Whole blood samples were collected by finger prick onto DBS cards, which were dried, packaged with desiccant, and shipped to the University of Washington for analysis. Two 50-μL DBS were eluted in 1.3-mL lysis solution, extracted by NucliSENS miniMag, and quantified using the Abbott Real Time HIV-1 m2000rt 1.0-mL protocol with a detection level of 520 copies/mL. Paired plasma samples were analyzed with the Roche COBAS AmpliPrep/COBAS TaqMan assay at Joint Clinical Research Centre facilities in Uganda. Correlations, sensitivity, specificity, and positive and negative predictive values were calculated to compare the two methods.
Results: Valid DBS and plasma results were obtained for 2663 patients. The correlation between log-transformed DBS and plasma measures was 0.673. At the 1000 copies/mL threshold, the DBS assay had 73.2% sensitivity, 97.2% specificity, 79.2% positive predictive value (PPV), and 96.1% negative predictive value (NPV). At the 5000 copies/mL threshold, DBS sensitivity was reduced to 49.5% with high specificity (99.5%), PPV (92.6%) and NPV (94.4%).
Conclusions: While the assay sensitivity improved at the lower threshold (1000 copies/mL), under field conditions the method was not sufficiently accurate to substitute for plasma measurement in determining treatment failure. Possible factors associated with low sensitivity include small spot sizes and sample degradation during storage. Further research is needed to improve assay sensitivity and develop scalable sample collection protocols.