Abstract Body

Background: A new HIV diagnostic algorithm has been proposed by the US CDC to improve acute HIV infection (AHI) detection and type differentiation of anti-HIV-1 from HIV-2 antibodies. The algorithm employs a 4th generation HIV-1/2 ELISA (4th gen) followed by the Multispot HIV-1/HIV-2 Rapid Test and nucleic acid testing, if indicated. We evaluated algorithm performance on well-characterized panels of serial samples collected from AHI cases identified by the Early Capture HIV Cohort (ECHO) Study, RV217. Methodology: Individuals at high risk of HIV infection from Tanzania, Uganda, Kenya and Thailand were screened twice-weekly by Aptima HIV-1 Qualitative RNA assay (Gen-Probe, Inc. San Diego, CA). Following a reactive (R) Aptima result, serial samples collected twice weekly from consenting participants were screened with GS Combo Ag/Ab EIA (4th Gen), GS HIV-1/2 Plus O EIA (3th Gen), HIV1/2 Multispot (Bio-Rad Laboratories, Redmond, Washington), HIV-1 p24 Antigen (Ag) Test (Bio-Rad, France) and Abbott m2000 real-time quantitative HIV RNA assay (Des Plaines, Illinois). In this algorithm, an individual is considered HIV uninfected if the 4th gen ELISA is non-reactive (NR), and HIV infected if a R 4th gen ELISA is confirmed by positive (POS) Multispot result. An individual is considered to be an AHI case, if the 4th gen ELISA is R, Multispot is negative, and HIV nucleic acids is detected. Results: Of 29 Acute HIV infection cases, only 7 were R by 4th gen ELISA at the earliest timepoint (median 2 days past R Aptima) with a detectable viral load. HIV-1 viral loads in the very early NR GS Combo samples ranged from 2.16 to 5.95 log10 copies/ml and were on the early viral upslope before peak viremia. In the 22 4th gen NR cases, p24 concentrations were lower than the package insert sensitivity of 50pg/ml. Five of seven (5/7) cases demonstrated R GS Combo results with p24 levels less than 50pg/ml (range 25-49 pg/ml). GS Combo reactivity was detected at a median 7 days (range 2-15) after the first reactive RNA test, 6 days before peak viral load, and 8 days before 3rd gen ELISA reactivity. Multispot reactivity was detected on median day 20. No HIV-2 infections were observed. Using the simulated algorithm, GS Combo reflexing to Multispot, in samples collected within the first 14 days post HIV-1 RNA positivity, 29/29 acute infections with p24 levels above 50pg/ml. Conclusions: The proposed US CDC algorithm identified 29/29 individuals with HIV-1 acute infection. Only 7/29 AHI cases were detected at the first visit when HIV-1 viremia and p24 concentration were low. This algorithm, with the addition of a 4th gen ELISA, enhances AHI detection sensitivity. Robust point of care HIV viral load detection would further reduce the diagnostic window, especially when screening most-at-risk cohorts.