Background: Ribavirin (RBV), a nucleoside analog, undergoes intracellular phosphorylation to a mono-(MP), di-(DP), and triphosphate (TP). RBV-TP accumulates in red blood cells (RBC) leading to ATP depletion, membrane oxidative damage, and ultimately hemolytic anemia. Therefore, measuring RBV-TP in RBC is of interest for pharmacokinetic/dynamic analyses. We describe the development and validation of a method to measure RBV-TP in RBC using dried blood spots (DBS) obtained from patients undergoing RBV-based treatment for chronic Hepatitis C virus (HCV) infection. Methodology: Whole blood was obtained in EDTA Vacu-tainer tubes from HCV infected subjects receiving RBV treatment for 1 day-48 weeks. Blood was used for two sample types, DBS and RBC. For DBS, a 3 mm punch was sonicated in 500 μL 70:30 methanol:water and the lysate was extracted using a QMA cartridge to separate TP from MP and DP followed by de-phosphorylation and another solid phase extraction to further purify RBV. For RBC, blood was centrifuged and RBC were obtained from the pellet, counted, and lysed in 5 mL 70:30 methanol:water followed by an identical extraction to the DBS. Concentrations were measured using liquid chromatography-mass spectrometry. DBS results are reported as pmol/punch and RBC as pmol/10^6 cells. Precision was determined in n=6 replicates of 3 patient samples in 3 separate extractions. Storage stability (room temp., 4°C, -20°C, -80°C) was assessed up to 310 days. Results: Samples were measured in an assay range of 0.5-200 pmol/sample. Precision was within 7.8% and 9.4% for inter- and intra-extraction, respectively. Samples kept at room temperature tested within }10.5% of immediate extraction up to 21 days post spotting. Long term storage stability was determined in 9 subjects at various points in treatment up to 48 weeks. Stability at room temperature tested at -40.1% to -83.4% compared to -80°C when stored for 196-310 days. A negative trend in 4°C stability was shown up to -20.1% compared to -80°C. Both -20 and -80°C storage conditions were comparable within }11.2%. Analysis of 10 paired DBS and RBC samples demonstrated an r^2 of 0.969 and an average of 10 million RBC/punch. Conclusions: Measurement of RBV-TP in DBS was shown to be precise, stability indicating up to 21 days at room temperature and at least 310 days when frozen. DBS correlated well to intracellular RBC concentrations. DBS offers many advantages for RBV-TP quantification in clinical trials because cell processing is eliminated, it requires a small blood volume, there is minimal processing time, little cost and there are no biological specimen shipping requirements.